REVO-E Heat pump 8 Removal/ installation of components (high-volt. syst.)
8.4 Refrigerant compressor removal/ installation
8.4.1 Remove the compressor
1. Preparation work, see 8.3.
2. Disconnecting the electrical lines
• Open the terminal box of the compressor using the
special key (attached to the compressor).
• Loosen electrical connections, see Fig. 606.
• Loosen lock nuts (3, Fig. 606) of the cable glands
for the 400V AC cable and pull the cable out of the
terminal box.
Fig. 804 (exemplarily)
1
2
3
4
1 Protective cover of compressor
2 Torx screws (6)
3 High-pressure / fluid connection
4 Low-pressure / suction connection
See torque table
Attachment A
Fig. 805 (exemplarily)
1 Cable gland for 400V AC
cable
2 Screws for retaining plate of
compressor pan (4x)
3 Screws for suction supply for
compressor (2x)
4 Screws for pressure plate on
compressor pan (4x)
5 Screws for suction pipe (2x)
1
2
3
4
5
See torque table
Attachment A