Series 651  INSTALLATION 
 
605451EC  Edition 2014-07-10  25/
 
4.4.2  Sensor supply concepts 
This valve offers 3 alternative concepts to supply the sensor(s) with power. This depends on the sensor 
type and valve version that is used. This valve is available with an optional sensor power supply module 
(SPS) that converts ±15 VDC from the 24 VDC. 
 
Concepts: 
 
• 
External +24 VDC supplied to POWER connector is feedthrough to SENSOR connector to supply 24 
VDC sensors. Refer to chapter «Power and sensor connection (+24 VDC sensors)» for schematic and 
correct wiring.  
• 
External ±15 VDC supplied to POWER connector is feedthrough to SENSOR connector to supply ±15 
VDC sensors. Refer to chapter «Power and sensor connection (±15 VDC sensors) without optional 
SPS module» for schematic and correct wiring. 
• 
External +24 VDC supplied to POWER connector is converted into ±15 VDC by the valve internal SPS 
and supplied to SENSOR connector to supply ±15 VDC sensors. Refer to chapter «Power and sensor 
connection (±15 VDC sensors) with optional SPS module» for schematic and correct wiring. 
 
 
 
This concept is only possible when SPS retrofit is installed. 
 
 
Valve versions: 
 
• 
651. . - . . G . - . . . .  and 651 . . - . . H . - . . . .    SPS module not included 
 
• 
651 . . - . . A . - . . . .  and 651 . . - . . C . - . . . .    SPS module included 
 
 
 
The SPS module can be retrofitted. Refer to chapter «Retrofit / replacement 
procedure» for instruction.