Series 651 OPERATION
605451EC Edition 2014-07-10 67/
99
5.6 Display information
There is a 4 digit display located on
the panel. It displays configuration,
status and position information. For
details refer to following tables.
5.6.1 Power up
Description Digit 1 Digit 2 Digit 3 Digit 4
Power On:
All dots are illuminated
# # # #
1
st
information for about 3s:
Firmware generation
[e.g. 1G..]
1 G
2
st
information for about 3s:
Firmware version and
firmware revision [e.g. 00 04]
0 0 0 4
3
nd
information for about 3s:
Valve type [e.g. .651]
6 5 0
4
nd
information for about 3s:
Controller configuration
In case D999 is displayed,
motor interlock is active. Refer
to «Safety mode» for details.
1
= Logic
interface
0
= basic
1
= with SPS
1)
2
= with PFO
2)
3
= with SPS
1)
and PFO
2)
1
= 1 sensor
version
2
= 2 sensor
version
SYNC indicates that powerup
synchronization is running.
S
Y
N C
1)
SPS = optional ±15 VDC Sensor Power Supply module,
2)
PFO = Power Failure Option
Display