Rotary lobe pump
Operating instructions
VX100Q/VX136Q/VX186Q, VX136QD/VX186QD, VX136QDM2/VX186QDM2
43/61
Pos: 213 /Übersc hriften/Überschrif t 3 /Dreholbe nwechsel - Ba ureihe VX136QD , VX186QD @ 58\mod_131 2809677379_48. doc @ 30918 2 @ 3 @ 1
8.7.2 Rotary lobe change - series VX136QD, VX186QD
Pos: 214 /WBV/P umpen/Instandse tzung/002 Kol benwechsel QD- Baureihe @ 58\mod_13 12888299375_4 8.doc @ 309332 @ @ 1
Fig. “Rotary lobe change, Q series"
1. Open QD cover (5) chap. "Opening the QD cover".
2. Pull the rotary lobes (11) from the shafts using a rotary lobe puller (see spare parts list).
Assemble HiFlo- and HiFloplus-Rotary lobes in pairs, i.e. simultaneously to the upper and the
lower shaft.
3. Install the new rotary lobes in reverse sequence Fig. "HiFlo and HiFloplus arrangement".
4. Close QD cover chap. "Closing the QD cover".
5. Apply pressure to buffer chamber chap. "Buffer chamber".