VX100Q/VX136Q/VX186Q, VX136QD/VX186QD, VX136QDM2/VX186QDM2
Pos: 249 /Übersc hriften/Überschrif t 1/Wartungspl an @ 59\ mod_13130594 97487_48.doc @ 3 09728 @ 2 @ 1
9 Maintenance plan
Pos: 250 /WBV/P umpen/Wartungspl an/002 Tabelle Wartungshi nweise @ 58\ mod_131236 3377882_48.doc @ 308134 @ @ 1
Before and after longer periods of non-use
After the first 10 operating hours
After the first 20 operating hours
Every 200 operating hours
Every 500 operating hours, at least every 3
months
Every 2000 operating hours, at least once a year
When there is severe contamination
Check belt tension for pumps with belt
drive acc. to accompanying sheet
Tighten the screws for the base
Checking buffer fluid tank or
quenching fluid tank
Changing buffer fluid or quenching
fluid
* chap. "Checklist before start-up"
Pos: 251 /WBV/P umpen/Warnhin weise/Maschi nengefahr/Gleitring dichtung SiC- SiC @ 58\ mod_13122747 37011_48.doc @ 307892 @ @ 1
Pumps with a mechanical seal consisting of the material combination SiC-SiC:
To avoid adhesion of the mechanical seal faces this pump needs to be rotated (at least one revolution) every
two months when not in service.