5-14 OM 803 us – Edition 3.7 * * 803b520.fm
Maintenance
Air filter (from serial no. AI00876)
Replacing air filter elements
Replace the air filter elements:
• If the yellow piston B in dirt indicator A reaches the red service mark C.
• Every 1000 operating hours or once a year at the latest.
1 Park the machine, stop the engine, remove the starting key and carry it with you.
2 Open the engine cover.
3 Remove dirt and dust from the air filter housing and the area around it.
4 Fold bow clips D on lower housing section E to the outside.
5 Remove lower housing section E.
M 6 Carefully remove outside filter G with slightly turning movements.
7 Ensure that all contamination (dust) inside the upper and lower housing sections
(including the dust valve) has been removed.
8 Clean the parts with a clean lint-free cloth, do not use compressed air.
9 Carefully remove inside filter H with slightly turning movements.
10 Check the new inside filter H and outside filter G for damage and carefully insert
them in the air filter housing.
11 Close bow clips D.
12 Ensure that dust valve F shows downward once it is installed.
13 After replacing the filters, press button J to reset the yellow piston B.
Fig. 199: Indicator for air filter contamination
A
C
B
J
F
E
Fig. 200: Lower housing section
D
Fig. 201: Outside filter
G
Fig. 202: Inside filter
H

Table of Contents

Other manuals for Wacker Neuson 803

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson 803 and is the answer not in the manual?

Wacker Neuson 803 Specifications

General IconGeneral
BrandWacker Neuson
Model803
CategoryExcavators
LanguageEnglish

Related product manuals