Initial commissioning
5661290000/00/06.08
31
CAUTION!
Never use damaged or worn out power
cables.
If you connect the PrintJet PRO to the
power supply via an extension cable,
ensure that the total nominal current of
all of the devices connected to the ex-
tension cable does not exceed the am-
pere rating for that extension cable. In
addition, you should ensure that the total
nominal current of all the devices
plugged into the wall-mounted socket
outlet does not exceed the ampere rat-
ing for that socket outlet.
CAUTION!
Do not carry out repairs to the device
yourself.
CAUTION!
Applicable in Germany: ensure when
connecting the PrintJet PRO to the
power supply that the building installa-
tion is protected by an appropriate back-
up fuse.
CAUTION!
Keep the mains cable (power cord) un-
damaged and keep it in its original state.
Do not place any heavy objects on it. Do
not pull at it with force and do not bend it
more than necessary. Ignoring these in-
structions can lead to electrocution or
fire.
Unplug the PrintJet PRO and contact a qualified
service engineer if any of the following occurs:
• The power cord is worn or damaged.
• The plug is worn or damaged.
Power supply
Connect the power cord to the PrintJet PRO and the
socket outlet (220-240 VAC or 100-120 VAC). Make
sure that the plug is completely inserted.
Top fuse:
10 A / delay-action 230 VAC
(12.5 A / delay-action 115 VAC) → Power circuit of
the fusing unit
Bottom fuse:
2 A / delay-action 230/115 VAC → Printer
controller
This device is subject to special conditions regarding
its connection to the mains power supply (for EU
Member States).
The supply impedance at the point of connection to
the public electricity supply must not exceed (0.14 +
i 0.09) Ohm. If it does, consult the power supply
company before connecting the device to the public
supply system.