9.1.4 Z Position at Pause
For general NK105 with double Z axes, the following parameters of Z1-axis should
be set to the same value with that of Z2-axis .
Position Option
Unit: -
Range: 0; 1; 2
Default value: 0
Effective: Immediately
Description: The positioning mode of Z-axis at pause.
0: to the specified distance.
1: to specified workpiece coordinate.
2: to specified machine coordinate.
Lifting Height
Unit: mm
Range: [0, 10000]
Default value: 10
Effective: Immediately
Description: The lifting height of Z-axis at pause when the parameter Position
Option is set to 1 or 2.
Z Work Coor
Unit: mm
Range: [-10000, 10000]
Default value: 10
Effective: Immediately
Description: The workpiece coordinate of Z-axis at pause when the parameter
Position Option is set to 1.
Z Mach Coor
Unit: mm
Range: [-10000, 10000]
Default value: 0
Effective: Immediately
Description: The machine coordinate of Z-axis at pause when the parameter
Position Option is set to 2.