上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
63 / 97
9.1.4 Z Position at Pause
For general NK105 with double Z axes, the following parameters of Z1-axis should
be set to the same value with that of Z2-axis .
Position Option
• Unit: -
• Range: 0; 1; 2
• Default value: 0
• Effective: Immediately
• Description: The positioning mode of Z-axis at pause.
– 0: to the specified distance.
– 1: to specified workpiece coordinate.
– 2: to specified machine coordinate.
Lifting Height
• Unit: mm
• Range: [0, 10000]
• Default value: 10
• Effective: Immediately
• Description: The lifting height of Z-axis at pause when the parameter Position
Option is set to 1 or 2.
Z Work Coor
• Unit: mm
• Range: [-10000, 10000]
• Default value: 10
• Effective: Immediately
• Description: The workpiece coordinate of Z-axis at pause when the parameter
Position Option is set to 1.
Z Mach Coor
• Unit: mm
• Range: [-10000, 10000]
• Default value: 0
• Effective: Immediately
• Description: The machine coordinate of Z-axis at pause when the parameter
Position Option is set to 2.