9.2.18 Safety Height
Safety Height
Unit: mm
Range: [0,5000]
Default value: 10
Effective: After restart
Description: The safety height is calculated with respect to workpiece origin.
And the horizontal movement at this height is considered to be safe. This
parameter is used in breakpoint resume and returning to workpiece origin.
9.2.19 Lubrication
Enable Auto Lube
Unit: -
Range: Yes; No
Default value: No
Effective: Immediately
Description: Whether to automatically enable lube at fixed period.
Time Interval
Unit: s
Range: [0, 34560000]
Default value: 5000
Effective: Immediately
Description: The time interval between two adjacent lubes.
Duration
Unit: s
Range: [0, 34560000]
Default value: 5
Effective: Immediately
Description: The duration to release lube every time.