上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
85 / 97
9.2.18 Safety Height
Safety Height
• Unit: mm
• Range: [0,5000]
• Default value: 10
• Effective: After restart
• Description: The safety height is calculated with respect to workpiece origin.
And the horizontal movement at this height is considered to be safe. This
parameter is used in breakpoint resume and returning to workpiece origin.
9.2.19 Lubrication
Enable Auto Lube
• Unit: -
• Range: Yes; No
• Default value: No
• Effective: Immediately
• Description: Whether to automatically enable lube at fixed period.
Time Interval
• Unit: s
• Range: [0, 34560000]
• Default value: 5000
• Effective: Immediately
• Description: The time interval between two adjacent lubes.
Duration
• Unit: s
• Range: [0, 34560000]
• Default value: 5
• Effective: Immediately
• Description: The duration to release lube every time.