76 / 97
Jump Speed
Unit: mm/min
Range: [Approach Speed, Machining Speed]
Default value: 0
Effective: Immediately
Description: The maximum speed for the stepper motor at start-up without
acceleration.
Look Ahead Dis
Unit: mm
Range: [0, 20]
Default value: 0.5
Effective: Immediately
Description: The look-ahead distance for velocity.
The system makes velocity plan based on the analysis of the current point.
Interp Dis
Unit: mm
Range: [0, 20]
Default value: 0.5
Effective: Immediately
Description: The look-ahead distance.
The system makes interpolation plan based on the analysis of the current point.
Max Angle
Unit: deg
Range: [0, 180]
Default value: 120
Effective: Immediately
Description: The maximum angle for high-speed connection.
When connecting angel is larger than this parameters, the system
automatically starts machining with jump speed without adjusting angle.
When connecting angel is smaller than this parameters, the system
calculates proper connecting speed according to connecting angle.