上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
76 / 97
Jump Speed
• Unit: mm/min
• Range: [Approach Speed, Machining Speed]
• Default value: 0
• Effective: Immediately
• Description: The maximum speed for the stepper motor at start-up without
acceleration.
Look Ahead Dis
• Unit: mm
• Range: [0, 20]
• Default value: 0.5
• Effective: Immediately
• Description: The look-ahead distance for velocity.
The system makes velocity plan based on the analysis of the current point.
Interp Dis
• Unit: mm
• Range: [0, 20]
• Default value: 0.5
• Effective: Immediately
• Description: The look-ahead distance.
The system makes interpolation plan based on the analysis of the current point.
Max Angle
• Unit: deg
• Range: [0, 180]
• Default value: 120
• Effective: Immediately
• Description: The maximum angle for high-speed connection.
– When connecting angel is larger than this parameters, the system
automatically starts machining with jump speed without adjusting angle.
– When connecting angel is smaller than this parameters, the system
calculates proper connecting speed according to connecting angle.