18
Indicator Technical Manua
l
Tare Settings Sub-block 3.x
Parameter Value Description
P3.0
Regulatory
0 = NTEP
1 = CANADA
2 = NONE <
Sets how the TARE operates based on regulatory agency.
NTEP: Allows a tare weight to be acquired at any positive
weight (>0).
Tares can only be cleared when GROSS weight is at no
load.
New tares may be acquired even if a previous tare weight
is present.
CANADA: Allows a tare weight to be acquired at any
positive weight (>0).
Tares can only be cleared when GROSS weight is at no
load.
Previous tare weights must be cleared before a new tare
weight can be acquired.
NONE: Allows a tare weight to be acquired at any positive
weight (>0).
Tares can be cleared at any time.
New tares may be acquired even if a previous tare weight
is present.
P3.1
Lockout Tare
0 = Disabled <
1 = Enabled
Locks out the TARE key. The Operator cannot tare the
scale.
P3.2
Auto Tare
0 = Disabled <
1 = Enabled
Automatically tares the scale when the weight is greater
than 5 displayed divisions, there is no motion, and the
scale is in GROSS mode.
P3.3
Auto Clear
0 = Disabled <
1 = Enabled
Automatically clears tare values when the scale is at
GROSS zero.
Factory default values are bold <.