EasyManua.ls Logo

Western Scale M2000 - User Manual

Western Scale M2000
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
* FOR SOFTWARE VERSION 1.45 *
* RELEASE DATE: FEB. 24th, 2004 *

Table of Contents

Other manuals for Western Scale M2000

Question and Answer IconNeed help?

Do you have a question about the Western Scale M2000 and is the answer not in the manual?

Summary

M2000 Introduction and Features

M2000 Indicators Overview

Overview of the M2000 digital weight indicator family and its applications.

M2000 System Features

Details on the performance, accuracy, versatility, and durability of the M2000 system.

M2000 Enclosures

Description of different M2000 models and their enclosure types.

M2000 Pre-Installation Procedures

Steps for receiving inspection and checking the M2000 indicator kit contents.

M2000 User Interface and Display

Explanation of the Alpha-Numeric Display and LED Indicator Lamps on the M2000.

M2000 Keypad and Key Functions

Describes the functions of the ON/OFF, ZERO SCALE, and CLEAR keys on the M2000 keypad.

Tare and Print;Select Key Operations

Explains the operation of the TARE and PRINT/SELECT keys for scale functions.

M2000 User Functions and Channel Selection

How to access and use M2000 functions, including selecting scale channels.

Total Mode (Summing Channels)

How to sum multiple scale channels for a total weight display in the M2000.

Scan Mode and Weighing Modes

Functions for scanning channels, changing between Gross/Net modes, and selecting units.

M2000 Security Features and Audit Trail

Information on electronic sealing, passwords, audit trail, and preventing unauthorized changes.

M2000 Battery Replacement

Procedures for testing and replacing the M2000's internal backup battery.

M2000 Installation Guide

M2000 Power Requirements

Specifies the necessary power quality and connections for M2000 indicators.

Grounding Requirements for M2000

Essential guidelines for proper grounding to prevent static and noise issues.

Accessing M2000 Terminals

Instructions for safely opening M2000 enclosures to access internal terminals.

M2000 A Wiring Terminals Configuration

Diagram and pin-out for M2000A PCB terminals, including COM, SMARTWIRE, and loadcells.

M2000 A Analog Loadcell Wiring

Wiring procedures for connecting analog loadcells to the M2000A.

Wiring Power to M2000 Indicators

Steps for correctly connecting the 12VDC power supply to the M2000.

M2000 Power Up and Troubleshooting

Steps for powering on the M2000 and common display issues and solutions.

M2000 Standard Calibration and Set-Up

Calibration Mode Operations

Overview of entering and operating within the M2000's Calibration Mode.

Calibration Mode Key Functions

Explains the keypad functions specific to the Calibration Mode.

Standard Scale Set-Up Parameters

Parameters for basic scale configuration like decimal points, graduations, and capacity.

Scale Calibration Parameters

Parameters related to scale calibration, including units and deadload.

Setting Span (Parameter 13)

Procedure for calibrating the scale's span using a known test weight.

M2000 Time and Date Settings

How to set the M2000's internal time and date, including format options.

M2000 Serial Communications

Serial Communications Set-Up

Configuration of serial ports, wiring, and default settings for M2000 communication.

Data Bits, Baud Rate, and Parity Settings

Settings for data bits, baud rate, and parity for serial communication.

M2000 Output String Format Options

Options for configuring the M2000's output string formats for various devices.

Serial Handshaking and Output Mode

Settings for serial handshaking (RTS/CTS) and string output modes.

Configure COM Ports for RS422 Mode

How to configure M2000 COM ports for RS422 communication.

Serial Output Routing and Transmission Delay

Routing serial output strings and setting transmission delays for COM ports.

Connecting M2000 to Hyper Terminal

Guide to connecting the M2000 to a PC using Hyper Terminal for data transfer.

Connecting Auxiliary Peripherals via Smartwire

Connecting Peripherals via Smartwire

Procedures for connecting M2000 auxiliary peripherals using the SMARTWIRE interface.

Smartwire Set-Up Parameters

Enabling and managing the SMARTWIRE port, including error handling.

4-20 mA Option Board Installation

Information on the 4-20mA current loop board and its connection.

Current Loop Offset and Span Adjustment

Setting the zero offset and span for the 4-20mA current loop output.

Setpoint Option Board Connection

Connecting and configuring the Setpoint option board for output control.

Setpoint Set-Up Parameters

Controlling the function of setpoints using the Setpoint Control Mask.

Entering Setpoint Values

Procedures for entering specific weight values for each setpoint.

Remote Input Option Board

Connecting and using the Remote Input board for external switch control.

Remote Input Board Functions

Supported remote functions like ZERO, TARE, CLEAR, GROSS, and PRINT.

M2000 Appendices

Appendix A - Parameter Listing

A comprehensive list of M2000 parameters, their functions, groups, and page references.

Appendix B - Error Codes

A list of M2000 error codes, their descriptions, and associated parameters.

Appendix C - Supported String Specifications

Details on various string formats supported by the M2000 for data output.

Appendix D - M2000 Specifications

Technical specifications covering performance, loadcells, communications, electrical, and approvals.

Appendix E - Warranty Information

Information regarding the warranty terms and conditions for the M2000.

Western Scale M2000 Specifications

General IconGeneral
BrandWestern Scale
ModelM2000
CategoryAccessories
LanguageEnglish

Related product manuals