HIGH SPEED DIGITAL WEIGHT INDICATORS
48
DISPLAY UPDATE RATE - PARAMETER 19
Description: The speed at which the M2000 displays changes in weight.
At a value of 0, the Update Rate is very fast and the display may
appear jittery in some applications. In this case, increase the
parameter value.
The Display (LED) Update Rate has nothing to do with the actual
A/D converter update rate or filtering.
PARAMETER VALUE DISPLAY UPDATE RATE
0 (default) No delay in the display update. Very fast.
Up to 9 (maximum) Maximum 3-second delay in display update.
SCALE OVER MESSAGE - PARAMETER 20
Description: Changes the way Scale Over (capacity) is displayed on M2000
indicators and how the condition will appear in the Output Strings.
If attempting to maintain compatibility with older Western Scale
equipment, set this parameter to 1.
PARAMETER VALUE SCALE OVER DISPLAY / TRANSMISSION
0 (default)
eeeeee
1
888888
SOUND VOLUME - PARAMETER 28
Description: This command controls the volume of the internal speaker.
PARAMETER VALUE ACTION
0
Sound off
1
Volume low
2 (default)
Volume medium
3
Volume high