EasyManua.ls Logo

Western Scale M2000 - Tare Offset; Tare Offset Flag

Western Scale M2000
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
TECHNICAL MANUAL
TARE OFFSET VALUE - PARAMETER 25
Description: This value represents a build up of material in the scale that
could come loose, resulting in an undesirable negative
weight.
At Scale Zero, the Centre of Zero LED will illuminate, but
the indicator display will show the tare offset value. This tare
weight is always present.
Default Value: 0 (No Tare Offset Value)
Accepted Values: Any weight
TARE OFFSET FLAG - PARAMETER 26
Description: This command controls the operating mode of the Tare
Offset.
PARAMETER VALUE DISPLAY EXAMPLE
0 (default)
Offset Disabled.
1
Legal For Trade Mode: M2000 cannot be put in NET
mode if no value has been set for tare. If a tare has
been entered, the Offset Value is included in the NET
display.
80
Not Legal For Trade Mode: Allows GROSS/NET
switching when the M2000 displays ZERO. If NET is
selected, the Offset Value is subtracted from the
displayed GROSS weight.
The following 2 parameters deal with TARE OFFSET and are
intended specifically for use in Grain Weighing applications.
There should be no reason to access these parameters for
an
y
other a
pp
lication or reason.

Table of Contents