HIGH SPEED DIGITAL WEIGHT INDICATORS
106
DF2500 COMMAND MODE 6
A fully interactive Command Set can be sent from a remote computer to operate
the indicator. This Command Mode has no checksum.
The maximum number of characters sent before the CR must not exceed 20.
The M2000 may fail to respond to the command if this number is exceeded.
Preceding the message with the STX insures the input buffer is cleared before
the next message. The indicator ignores LF and other control characters.
The following is a list of commands that can be executed:
COMMAND DATA REQ’D. FUNCTION
G
None
Set to GROSS mode and send string
N
None
Set to NET mode and send string
P
None
Tare scale & send NET string (0)
T
Tare Weight
(left pad with spaces)
Set tare weight and send NET string
R
None
Recall tare weight
C
None
Clear tare weight & send GROSS string
?
None
Poll for weight (any mode)
L
None
Set units to LB & send string (any mode)
K
None
Set units to KG & send string (any mode)
Z
None
Zero the scale & send string (any mode)
A
None
Add to accumulator
S
None
Recall accumulator
B
None
Recall load counter
X
None
Clear accumulator
1
Setpoint 1
(left pad with spaces)
Enter Setpoint 1
2
Setpoint 2
(left pad with spaces)
Enter Setpoint 2
3
Setpoint 3
(left pad with spaces)
Enter Setpoint 3
4
Setpoint 4
(left pad with spaces)
Enter Setpoint 4
5
Setpoint 5
(left pad with spaces)
Enter Setpoint 5
6
Setpoint 6
(left pad with spaces)
Enter Setpoint 6