SPAN FACTOR (SET SPAN) - PARAMETER 110
Description: Displays and allows entry of a Calibration Span factor. Field
Service Technicians can instantly calibrate the M2000 to a
specified value.
This feature is useful for replacing an indicator when a full span
cannot be carried out, and for easily resetting the scale’s calibration
when experimenting with calibration solutions.
Accepted Values: Numeric. Up to 6 digits (No decimals)
EXAMPLE: ENTERING THE SPAN FACTOR ON A REPLACEMENT
INDICATOR.
1. On the old indicator, enter Parameter 110. The scale’s Span Factor (a
number) will be displayed.
2. Connect the new indicator to the scale. If possible, Deadload the scale
(See Parameter 12 - Page 32) before proceeding.
3. Enter Parameter 110. A Span Factor is displayed. Enter the Span Factor
(number) from the old indicator followed by the [PRINT/SELECT] key.
THE SCALE MUST BE DEADLOADED AT SOME POINT
DURING THIS PROCESS!