HIGH SPEED DIGITAL WEIGHT INDICATORS
22
M2000A ANALOG LOADCELL WIRING
Loadcell connections are labeled as follows:
LABEL CONNECTION
- EXC Negative Excitation
- SNS Negative Sense
+ SNS Positive Sense
+ EXC Positive Excitation
SHLD Loadcell Shield
- SIG Negative Signal
+ SIG Positive Signal
SCALE SYSTEMS WITH ONE LOADCELL ONLY
The Loadcell is wired directly to the M2000A using a 7 pin terminal connector.
The connector can be unplugged from the M2000 to make wiring easier.
Pass the loadcell cable through the strain-relief, into the enclosure (Not
required for Slimline models).
Terminate the loadcell wires, according to the Loadcell Connection table
above. Make sure each wire is securely fastened in the appropriate
position.
Plug the connector into the appropriate terminal (Scale Channel).
Re-assemble the M2000 enclosure as necessary.
-EXC
-SNS
+EXC
SHLD
-SIG
+SIG
+SNS
CHANNEL 1
BE SURE TO CHECK THE LOADCELL MANUFACTURER’S
INSTRUCTIONS FOR THE CORRECT WIRE COLOUR CODE.