HIGH SPEED DIGITAL WEIGHT INDICATORS
30
STANDARD SCALE SET-UP PARAMETERS
The following parameters are standard for getting a scale up and running.
DECIMAL POINT POSITION - PARAMETER 2
Description: Sets the number of decimal places to correspond with Grad Size.
PARAMETER VALUE DISPLAY EXAMPLE
0 (default) 123456.
1 12345.6
2 1234.56
3 123.456
4 12.3456
GRADUATION SIZE - PARAMETER 3
Description: The number the scale will count by.
PARAMETER VALUE DISPLAY EXAMPLE
1 (default) 1, 2, 3, etc.
2 2, 4, 6, etc.
5 5, 10, 15, etc.
10 10, 20, 30, etc.
20 20, 40, 60, etc.
50 50, 100, 150, etc.
100 100, 200, 300, etc.
SCALE CAPACITY - PARAMETER 4
Description: True Scale Capacity. The Zero Range is calculated from this value.
Accepted Parameter Values: Any number (weight) up to 999999.
For “Scale Over” above True Scale Capacity, see Parameter 8 –
Page 46.