23
Indicator Technical Manua
Additional Scale Functions Sub-block 8.x
Parameter Value Description
P8.0
Peak Hold
0 = Disabled <
1 = Enabled
2 = No Motion
Enables the Peak Hold function. The maximum
weight is captured and displayed until the
CLEAR key is pressed.
When set to 2, peak weights are only captured
when there is no Motion on the scale.
P8.1
Peak Hold
Threshold
000000 <
Enter the minimum weight that must be exceeded
before the Peak Hold function activates. The
weight must fall below this threshold before
another Peak Hold can be performed. Use the
ARROW keys to edit the value, followed by the
ENTER key.
P8.2
Peak Hold
Auto-Clear
0 = Disabled <
1 = Enabled
Automatically clears the Peak Hold display when
the scale weight drops below the Peak Hold
Threshold (P8.1).
P8.3
Peak Hold
Timer
0 <
Range: 0 - 20
(0 to 5 sec)
Delays Peak Hold activation by the selected
amount of time (in 0.25 second intervals). Useful
for lifting applications where there is a strong
initial force that may cause an exaggerated Peak
Hold display.
Example: For a delay of 1 second, set this value
to 4.
Factory default values are bold <.