5-10 Troubleshooting
Problem: The operating mode you selected (i.e., One-hand, Two-hand, or Foot) is not valid
for your stroke selection (i.e., Inch, Single-stroke, or Continuous).
Remedy: Refer to the discussion of operating modes starting on page 4-8 to determine the
correct operating mode for your stroke selection.
Problem: Both Run/Inch palm buttons on the Operator Station were pressed in One-hand
mode
or
Run/Inch buttons on an unselected Operator Station were pressed in a
dual-Operator-Station setup.
Remedy: Press only one Run/Inch palm button when running the press in One-hand mode
or
Select both Operator Stations in a dual-Operator-Station setup, then initiate a
stroke.
Problem: The flywheel speed sensor is not turning off and on properly when spin-down is
enabled.
Remedy: For Bliss non-integrated, disable by connecting pin #26 to +24 Vdc.
Problem: The flywheel turned faster than 6 SPM while the press was in Bar mode, creating a
potentially unsafe barring condition.
Remedy: After clearing the error, bar the press more slowly. Refer to Operating the Press in
Bar Mode, page 4-19.