Page #184 background imageLoading...
Page #184 background image
WPC 2000 User Manual 1128500
Troubleshooting 5-15
Problem: A light curtain is connected with Two-hand Only firmware installed in WPC 2000.
Remedy: Remove the Two-hand Only firmware, and install a firmware version intended for
use with a light curtain, referring to Installing Revised Firmware in WPC 2000,
page 2-49. Contact Wintriss Tech. Support for help in selecting the right firmware
for your application.
Emergency-stop Circuit Driver Failure
Problem: The Emergency-stop input circuit driver has failed or is about to fail.
Remedy: Check E-stop circuit wiring, and correct any problems. If the error persists after
you reset the unit, contact Wintriss Tech. Support for assistance or replacement of
the driver.
Top-stop Circuit Driver Failure
Problem: The Top-stop input circuit driver has failed or is about to fail.
Remedy: Check Top-stop circuit wiring, and correct any problems. If the error persists after
you reset the unit, contact Wintriss Tech. Support for assistance or replacement of
the driver.