Software | Care
Rinsing
Rinsing starts. This part of the routine takes about 40min.
When requested refill with fresh cold water (once after
about 16min, and again after approx. 32min)
Empty collection container
After the final rinsing the steam boiler is heated up. The
hot water expands and finally exits briefly as steam.
The descaling is complete. Completion is indicated on the
display.
Descaling coffee machine with constant water supply
Preparation
Remove water tank
Turn off main water supply tap
Turn and remove seal plug on water tank connector
counter-clockwise (flat screwdriver, see illustration
1and2)
Stir liquid descaling agent in water tank with warm
water
If crystals have formed when stored below the freezing
point, stir until all crystals present in the liquid
descaling agent have dissolved
Descaling
Replace the water tank filled with descaling solution,
and confirm on the display
Descaling starts. This part of the routine takes about
40min.
Remove water tank and empty out remaining descaling
solution
Rinse water tank and fill to maximum with cold water.
See the markings on the outside of the water tank.
Replace the water tank
Caution
Hot steam.
Observe the Safety chapter.
Crystals may form in the liquid
descaling agent when stored.
The crystals must not enter the
machine.
The ideal water temperature is
approx. 37°C.