Specifications
Chains
8
8-3 60doc081208 Specifications
8.4 Chains
See Table 8-5. The load capacity of the chains is listed below.
8.5 Hydraulic System
See Table 8-6. The specifications of the hydraulic system are shown below.
2.The measured values refer to emission levels, not necessarily to noise levels in the
workplace. Although there is a relation between emission levels and exposure levels, it is
not possible to determine with certainty if preventives are needed or are not needed. The
factors affecting a current level of noise exposure during work are inter alia room
characteristics and characteristics of other noise sources, e.g. number of machines and
machining operations nearby. Also, the permissible exposure level value may vary
depending on country. This information enables the machine’s user to better identify
hazards and a risk.
Load Capacity According to ISO No 08A-1
Power Feed Chain 22700N
Up/Down Chain 45400N
TABLE 8-5
Hydraulic Pump #M-300-0230 Monarch
Pressure Rating 17,25MPa (2500 PSI)
Max. Pressure 19MPa (2750 PSI)
TABLE 8-6