Maintenance
Vertical Mast Rails
Maintenance 60HDdoc081208 5-8
5
5.5 Vertical Mast Rails
Clean and lubricate the vertical mast rails every 50 hours of operation. Clean with solvent
and remove any rust with a light-grade sand paper or emery cloth. Lubricate the mast with
motor oil or automatic transmission fluid (ATF).
CAUTION! Never use grease on the mast rails as it will col-
lect sawdust.
5.6 Drum Switches
Lubricate the up/down and power feed drum switch contacts inside the control panel
every fifty hours of operation. Use only contact grease supplied by Wood-Mizer. Remove
the control panel cover. Use a cotton swab to apply grease to the switch contact ends.
WARNING! Drum switch grease contains Petroleum Hydro-
carbon Lubricant. Eye and skin irritant. If introduced into
eyes, flush with water for at least 15 minutes. If film or irrita-
tion persists, seek medical attention. Wash skin with soap
and water. If ingested, do not induce vomiting - contact a
physician. KEEP OUT OF THE REACH OF CHILDREN.
50
50