Maintenance
Hydraulic System
Maintenance 60HDdoc081208 5-18
5
3. Inspect the hydraulic pump motor brushes every 750 hours of operation. Remove brush
dust and replace the brushes if they worn to a length of 1/4” or shorter.
CAUTION! Do not operate the hydraulic system if the pump
motor brushes are worn shorter than 1/4”. Damage to the
pump motor may result.
4. Periodically check all hydraulic lines and fitting as needed. Replace as necessary.
750