Troubleshooting Guide
Electrical Problems
6
6-4 60HDdoc081208 Troubleshooting Guide
PROBLEM CAUSE SOLUTION
Up/Down Or Power Feed
Motors Overheat And Lose
Power.
System overload or bind
occurred.
Correct problem (See Section
6.3 ). Allow motor to cool
before restarting.
Normal operation factors
exceeded (eg: up/down con-
trol jockeyed excessively).
Allow motor to cool before
restarting.
Everything Works And Then
Cuts Out - Works Again.
Bad battery, fuse, or ground
connection.
Check and tighten connec-
tions.
Nothing Works Electrically. Dead battery. Check for short circuit or turn
OFF key.
Blown fuse. Replace.
Corrosion on battery post. Remove connection and clean
posts.
Loose connections at LED cir-
cuit board or alternator.
Check and tighten connec-
tions.
Intermittent Or Permanent
Loss Of Accessory Motor
Functions Occurs
(Up/down, Fwd/rev, Blade
Guide Functions Do Not
Work).
Bad connections at accessory
solenoid or bad solenoid.
Check all connections at
accessory solenoid. If connec-
tions are good, replace sole-
noid.