C-5000 COMMUNICATION MANAGEMENT CONTROLLER
INSTALLATION MANUAL
Publication No. 150-041118 Page 5-31
Rev. A Section 5 – Configuration and Programming
Sep 2001
PROG: 2=NEXT 3=BACK
3RD IF INJECTION= HI
• Use the cursor/value knobs to input the channel’s third I.F. Injection as HI or LO. The default is LO. Press the
MODE button to go to the next menu page.
PROG: 2=NEXT 3=BACK
RX AUDIO PHASE= 0
• Use the cursor/value knobs to input the channel’s receive audio phase as 0 or 180. The default is 0. Press the
MODE button to go to the next menu page.
PROG: 2=NEXT 3=BACK
TX AUDIO PHASE= 0
• Use the cursor/value knobs to input the channel’s transmit audio phase as 0 or 180. The default is 0. Press the
MODE button to go to the next menu page.
PROG: 2=NEXT 3=BACK
TX DEVIATION= 5.0KHZ
• Use the cursor/value knobs to input the channel’s transmit deviation. This can be 3.0KHz, 5.0KHz, 4.0KHz, or
5.6KHz. The default is 5.0KHz. Press the MODE button to go to the next menu page.
PROG: 2=SAVE 3=BACK
..1 PRESET CHAN1
• Press the MODE button to permanently save the channel and return to the CHANNEL MAIN MENU PAGE.
You may also review your changes by pressing the EDIT button, or cancel the operation by pressing the HOME
button.