Insulation Blowing Machine M99
Page 48 of 51
X-Floc Dämmtechnik-Maschinen GmbH
Rosine-Starz-Straße 12 · 71272 Renningen · Germany
Phone +49-7159-80470-30 · Fax -40 | info@x-floc.com · www.x-floc.com
7.2.5 Parameter List for the Frequency Convertor M99-DS und M99-DS-Pro
Code Term X-Floc Settings Factory Settings
ACC Ramp-up time 2,0
Sec. 3,0
Sec.
dEC Deceleration time 1,0
Sec. 3,0
Sec.
LSP Small frequency 30,0
Hz 0
Hz
HSP Large frequency 70,0
Hz 50,0
Hz or 60,0
Hz
tFr Max. output frequency 70,0
Hz 60,0
Hz
nPr Engine power 0,75
kW 0,75
kW
Allt Configured set point input 10,0
V 5,0
V
nCr Nominal motor rated current 3,3
A 3,5
A
ltH Nominal thermal motor 3,6
A 3,5
A
nSP Rated engine speed 1380-1390
R/min. 1400
R/min.
Ctt Engine control type PErF Hrs.
COS Cosine Phi 0,76 0,77
SLP Slip compensation 7% 100%
rrS Counter-clockwise rotation L2H NO
Unlisted parameters can be found in factory settings.
7.2.6 Technical Details FFB
400
Hand-held control
Dimensions (W×H×D) 22×65×120
mm
Operating frequency f1
=
433,62
MHz, f2
=
434,22
MHz
Supply 2×AAA-cells (2,0-3,5
V DC)
Operating temperature -10°C to +65°C
Storage temperature -40°C to +85°C
Receiver
Dimensions (W×H×D)
45×82×113
mm
Operating frequency f1
=
433,62
MHz, f2
=
434,22
MHz
Power supply 12-24
V AC/DC
Operating temperature -10°C to +65°C
Storage temperature -40°C to +85°C
Protection category II (VDE0700/IEC335/EN60335)
Electronic output 3 (Air, Material, AUX), max. load 0,25
A
Relay outputs 3 (Air, Material, AUX), max. load 30,0
V / 5,0
A
All values are approximate values.