Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0 129
To check a triggered setpoint:
SOUR:VOLT:TRIG?
SOUR:CURR:TRIG?
SOUR:POW:TRIG?
To set limits:
SOUR:VOLT:LIM:HIGH <voltage>
SOUR:VOLT:LIM:LOW <voltage>
SOUR:CURR:LIM:HIGH <current>
SOUR:CURR:LIM:LOW <current>
SOUR:POW:LIM:HIGH <power>
SOUR:POW:LIM:LOW <power>
If the high end of the range was set to 5 volts, the command, SOUR:VOLT 10 would
return an error.
To check ranges:
SOUR:VOLT:LIM:HIGH?
SOUR:VOLT:LIM:LOW?
SOUR:CURR:LIM:HIGH?
SOUR:CURR:LIM:LOW?
SOUR:POW:LIM:HIGH?
SOUR:POW:LIM:LOW?
Example:
To set voltage to 5.5V and current limit to 100A, send the command:
:VOLT 5.5; :CURR 100
Then check the output:
MEAS:VOLT? 5.500 (example readback, default unit V)
MEAS:CURR? 0.010 (example readback, default unit A)
MEAS:POW? 0.005 (example readback, default unit W)