Parameter List
11
11.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
YASKAWA SIEPC71061753C GA500 Technical Manual 463
No. Name Range Unit
Control Method (A1-02 Setting)
OLV/PM
(5)
AOLV/PM
(6)
EZOLV
(8)
L3-21
OVSuppression Accel/
Decel P Gain
0.10 - 10.00 0.01 1.00 1.00 1.00
L3-36
Current Suppression
Gain@Accel
0.0 - 100.0 0.1 - - -
L4-01
Speed Agree Detection
Level
0.0 - 400.0
*1
0.1 0.0 Hz 0.0% 0.0%
L4-02
Speed Agree Detection
Width
0.0 - 20.0
*2
0.1 2.0 Hz 4.0% 4.0%
L4-03
Speed Agree Detection
Level(+/-)
-400.0 - +400.0
*5
0.1 0.0 Hz 0.0% 0.0%
L4-04
Speed Agree Detection
Width(+/-)
0.0 - 20.0
*2
0.1 2.0 Hz 4.0% 4.0%
L8-40
Carrier Freq Reduction
Off-Delay
0.00 - 2.00 0.01 s 0.00 0.00 0.00
L8-90
STPo Detection Level
(Low Speed)
0 - 5000 1 0 80 -
n5-04
Speed Response
Frequency
0.00 - 500.00 0.00 Hz - 20.00 -
n8-35
Initial Pole Detection
Method
0 - 2 1 0 1 -
n8-51
Pull-in Current @
Acceleration
0 - 200% 1 50% 0 80%
o1-03
Frequency Display Unit
Selection
0 - 3 1 0 1 1
o1-04 V/f Pattern Display Unit 0 - 1 1 - 1 -
*1 The setting range is 0.0 to 100.0 when A1-02 = 6 [PM Advanced Open Loop Vector].
*2 The setting range is 0.0 to 40.0 when A1-02 = 6 [PM Advanced Open Loop Vector].
*3 The default setting changes when the setting for C6-01 [Normal / Heavy Duty Selection] changes.
*4 This is the value for 200 V class drives. Double the value for 400 V class drives.
*5 The setting range is -100.0 to +100.0 when A1-02 = 6 [PM Advanced Open Loop Vector].