EasyManua.ls Logo

YASKAWA CIPR-GA50CB001

YASKAWA CIPR-GA50CB001
794 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Details
12
12.5 d: References
YASKAWA SIEPC71061753C GA500 Technical Manual 581
Figure 12.60 shows the Offset frequency function:
Figure 12.60 Offset Frequency Operation
d7-01: Offset Frequency 1
No.
(Hex.)
Name Description
Default
(Range)
d7-01
(02B2)
RUN
Offset Frequency 1
Uses H1-xx = 44 [MFDI Function Select = Add Offset Frequency 1 (d7-01)] as a percentage of
the Maximum Output Frequency to add or subtract the set frequency to/from the frequency
reference.
0.0%
(-100.0 - +100.0%)
d7-02: Offset Frequency 2
No.
(Hex.)
Name Description
Default
(Range)
d7-02
(02B3)
RUN
Offset Frequency 2
Uses H1-xx = 45 [MFDI Function Select = Add Offset Frequency 2 (d7-02)] as a percentage of
the Maximum Output Frequency to add or subtract the set frequency to/from the frequency
reference.
0.0%
(-100.0 - +100.0%)
d7-03: Offset Frequency 3
No.
(Hex.)
Name Description
Default
(Range)
d7-03
(02B4)
RUN
Offset Frequency 3
Uses H1-xx = 46 [MFDI Function Select = Add Offset Frequency 3 (d7-03)] as a percentage of
the Maximum Output Frequency to add or subtract the set frequency to/from the frequency
reference.
0.0%
(-100.0 - +100.0%)
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA CIPR-GA50CB001

Related product manuals