12.11 o: Keypad-Related Settings
762 YASKAWA SIEPC71061753C GA500 Technical Manual
■ o1-41: 1st Monitor Area Selection
No.
(Hex.)
Name Description
Default
(Range)
o1-41
(11C1)
RUN
1st Monitor Area Selection
Sets the horizontal axis value used to display the monitor set in o1-24 [Custom Monitor 1] as a
bar graph. This parameter is only available with an LCD keypad.
0
(0 - 1)
0 : +/- Area ( - o1-42 ~ o1-42 )
1 : + Area ( 0 ~ o1-42 )
■ o1-42: 1st Monitor Area Setting
No.
(Hex.)
Name Description
Default
(Range)
o1-42
(11C2)
RUN
1st Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in o1-24 [Custom Monitor 1] as a
bar graph. This parameter is only available with an LCD keypad.
100.0%
(0.0 - 100.0%)
■ o1-43: 2nd Monitor Area Selection
No.
(Hex.)
Name Description
Default
(Range)
o1-43
(11C3)
RUN
2nd Monitor Area Selection
Selects the horizontal range used to display the monitor set in o1-25 [Custom Monitor 2] as a bar
graph. This parameter is only available with an LCD keypad.
0
(0 - 1)
0 : +/- Area ( - o1-44 ~ o1-44 )
1 : + Area ( 0 ~ o1-44 )
■ o1-44: 2nd Monitor Area Setting
No.
(Hex.)
Name Description
Default
(Range)
o1-44
(11C4)
RUN
2nd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in o1-25 [Custom Monitor 2] as a
bar graph. This parameter is only available with an LCD keypad.
100.0%
(0.0 - 100.0%)
■ o1-45: 3rd Monitor Area Selection
No.
(Hex.)
Name Description
Default
(Range)
o1-45
(11C5)
RUN
3rd Monitor Area Selection
Sets the horizontal axis value used to display the monitor set in o1-26 [Custom Monitor 3] as a
bar graph. This parameter is only available with an LCD keypad.
0
(0 - 1)
0 : +/- Area ( - o1-46 ~ o1-46 )
1 : + Area ( 0 ~ o1-46 )
■ o1-46: 3rd Monitor Area Setting
No.
(Hex.)
Name Description
Default
(Range)
o1-46
(11C6)
RUN
3rd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in o1-26 [Custom Monitor 3] as a
bar graph. This parameter is only available with an LCD keypad.
100.0%
(0.0 - 100.0%)
■ o1-47: Trend Plot 1 Scale Minimum Value
No.
(Hex.)
Name Description
Default
(Range)
o1-47
(11C7)
RUN
Trend Plot 1 Scale
Minimum Value
Sets the horizontal axis minimum value used to display the monitor set in o1-24 [Custom Monitor
1] as a trend plot. This parameter is only available with an LCD keypad.
-100.0%
(-300.0 - +299.9%)
Note:
Parameter o1-48 [Trend Plot 1 Scale Maximum Value] sets the upper limit. The upper limit is (o1-48 - 0.1)%.