10 Drive Start-Up Procedure
54 YASKAWA TOEPC71061737B GA800 Drive Installation & Primary Operation
3. Push or to select [Parameters], then push .
4. Push or to select [C Tuning], then push .
5. Push or to select [C1 Accel & Decel Time], then push .
6. Push or to select C1-01, then push .
7. Push or to select the specified digit, then push or to select the correct number.
Push [Default] to set the parameter to factory default.
Push [Min/Max] to show the minimum value or the maximum value on the display.
8. Push to keep the changes.
9. Continue to change parameters, then push [Back], [Home] to go back to the home screen after
you change all the applicable parameters.