7 Configuration and Maintenance of MLX200 Control Module
7.2 Maintenance and Configuration Operations
7-10
168542-1CD
168542-1CD
MLX200 Software and
Operations
Fig. 7-14: Selecting Log Files Operations
The user can choose to download all log files, or just the log files
pertaining to the last run of MLX-R.exe. Select an appropriate operation
and then click on the [Execute] button. The log files selected will be
downloaded to the USB disk inserted on the MLX200 Control Module. The
downloaded log files will be written to a folder on the USB Disk with the
folder name including a time stamp of the operation. The folder name
used for the operation will be displayed in the message box area towards
the bottom of the screen.
7.2.6 Updating Configuration and License Files
The MLX200 Control Module contains configuration files and license files
that describe the robot cell configuration to the MLX200 PLC Interface
Application. In certain situations, it may be necessary to update these
files. For example, a new license file may need to be uploaded to enable
an optional feature or a new configuration file may need to be uploaded
due to a change in hardware configuration. In some cases, a support
person from the manufacturer or system integrator might need to review
the current license or configuration file in order to troubleshoot a problem.
These operations can be performed from the {Maintenance Operations}
screen.
In order to download the current configuration file or license file to a USB
Disk, click on the “Download/Backup” category on the left and select the
respective operation in the middle as shown in Fig.7-15 "Selecting a
Download Operation".
All download operations from the {Maintenance} screen
including the download log file operations require a USB
Disk inserted into an available USB port on the MLX200
Control Module.