7 Configuration and Maintenance of MLX200 Control Module
7.2 Maintenance and Configuration Operations
Fig. 7-22: Selecting the Firmware Update Operation
Click on the [Execute] button after selecting the update operation. A new
pop-up dialog will be shown as shown in Fig.7-23 "Selecting the Folder
Containing Firmware Update Files" that allows the user the select the
folder in the USB disk that contains the firmware update files.
Fig. 7-23: Selecting the Folder Containing Firmware Update Files
Select the folder that contains the firmware update files and click the
[Select] button. The Maintenance Tool will first perform verification of the
integrity of the update files and then prepare the Control Module for the
update operation. Once this preparation is complete, the actual firmware
update task will be performed after a reboot of the Control Module. Follow
the procedure outlined in Section 7.2.4 “Rebooting the MLX200 Control
Module” in order to reboot and complete the firmware update operation.
After the MLX200 Control Module is rebooted to perform the update
operation, the {Status display} screen will show the results of the firmware
update operation as shown in Fig.7-24 "Status Display Showing Firmware
Update Result".