User Constant Tables
5-
15
* 1. The factory setting will change when the control method is changed. The open-loop vector 1 factory settings are given.
* 2. Applicable for G7-Series Inverters with software versions PRG 1039 and later.
b3-10
Speed
search
detection
compensa-
tion gain
(speed cal-
culation)
Operation restarts at a speed
obtained by multiplying the
speed from the speed search by
the compensation gain (exci-
tation search only.)
Increase this setting if over-
voltages occur when a speed
search is performed after a
long baseblock, for example, in
searches at startup.
1.00 to
1.20
1.10 No A No A No A 19AH 6-66
Srch Detect
Comp
b3-13
Propor-
tional gain
of the speed
estimator
during
speed search
Sets the proportional gain (PI
control) of the speed estimator
during speed search taking the
setting of N4-08 as equivalent
to a setting of 1.0.
Usually, there is no need to
change this setting. If, how-
ever, the load inertia is large
and overvoltages occur during
the search, reduce this setting.
Increase this setting for greater
speed coincidence response.
0.1 to
2.0
1.0% No No No No No A 19DH 6-67
Srch Est P
Gain
b3-14
Rotation
direction
search
selection
0: Disabled (operates with
specified rotation direction)
1: Enabled (operates with
rotation direction found by
search)
0 or 1 1 No A A A No A 19EH 6-67
Bidir Search
Sel
b3-17
*2
Speed
search
retrial cur-
rent level
(speed esti-
mation)
Sets the current level to retry a
speed search as a percentage,
taking the Inverter rated cur-
rent as 100%.
0 to
200
150% No A No A No A 1F0H 6-67
SrchRestart
Lv1
b3-18
*2
Speed
search
retrial detec-
tion time
(speed esti-
mation)
Sets the time for detection in a
speed search retrial in units of
seconds.
0.00 to
1.00
0.10 s No A No A No A 1F1H 6-67
SrchRestart
Time
b3-19
*2
Number of
speed search
retrials
Sets the number of times that a
speed search can be retried.
0 to 10 0 No A No A No A 1F2H 6-67
Num of
SrchRestr
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
TOE-S616-60.1.book 15 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals