User Constant Tables
5-
41
F1-05
PG rotation 0: Phase A leads with
Forward Run Command.
(Phase B leads with
Reverse Run Command.)
1: Phase B leads with
Forward Run Command.
(Phase A leads with
Reverse Run Command.)
0 or 1 0 No No A No A No 384H
6-160
PG Rotation
Sel
F1-06
PG division
rate (PG
pulse moni-
tor)
Sets the division ratio for the
PG speed control board pulse
output.
Division ratio = (1+ n) /m
(n = 0 or 1 m = 1 to 32)
This constant is only effective
when a PG-B2 is used.
The possible division ratio
settings are: 1/32 F1-06 1.
1 to
132
1NoNoANoANo385H
6-161
PG Output
Ratio
F1-07
Integral value
during accel/
decel enable/
disable
Sets integral control during
acceleration/deceleration to
either enabled or disabled.
0: Disabled (The integral
function isn't used while
accelerating or
decelerating; it is used at
constant speeds.)
1: Enabled (The integral
function is used at all
times.)
0 or 1 0 No No A No No No 386H
6-161
PG Ramp PI/I
Sel
F1-08
Overspeed
detection
level
Sets the overspeed detection
method.
Frequencies above that set for
F1-08 (set as a percentage of
the maximum output fre-
quency) that continue to
exceed this frequency for the
time set in F1-09 are detected
as overspeed faults.
0 to
120
115% No No A No A A 387H
6-161
PG Overspd
Level
F1-09
Overspeed
detection
delay time
0.0 to
2.0
0.0 s
*
No No A No A A 388H
6-161
PG Overspd
Time
F1-10
Excessive
speed devia-
tion detec-
tion level
Sets the speed deviation
detection method.
Any speed deviation above
the F1-10 set level (set as a
percentage of the maximum
output frequency) that contin-
ues for the time set in F1-11 is
detected as a speed deviation.
Speed deviation is the differ-
ence between actual motor
speed and the reference com-
mand speed.
0 to 50 10% No No A No A A 389H
6-161
PG Deviate
Level
F1-11
Excessive
speed devia-
tion detec-
tion delay
time
0.0 to
10.0
0.5 s No No A No A A 38AH
6-161
PG Deviate
Time
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
F1-06 ڧ ڧڧ
nm
TOE-S616-60.1.book 41 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals