Page #177 background image
User Constant Tables
5-
45
Digital Output Boards (DO-02C and DO-08): F5
User constants for the Digital Output Board are shown in the following table.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
F5-01
Channel 1
output selec-
tion
Effective when a Digital Out-
put Board (DO-02C or DO-
08) is used.
Set the number of the multi-
function output to be output.
0 to 37 0 No A A A A A 399H
6-164
DO Ch1
Select
F5-02
Channel 2
output selec-
tion
Effective when a Digital Out-
put Board (DO-02C or DO-
08) is used.
Set the number of the multi-
function output to be output.
0 to 37 1 No A A A A A 39AH
6-164
DO Ch2
Select
F5-03
Channel 3
output selec-
tion
Effective when a DO-08 Dig-
ital Output Board is used.
Set the number of the multi-
function output to be output.
0 to 37 2 No A A A A A 39BH
6-164
DO Ch3
Select
F5-04
Channel 4
output selec-
tion
Effective when a DO-08 Dig-
ital Output Board is used.
Set the number of the multi-
function output to be output.
0 to 37 4 No A A A A A 39CH
6-164
DO Ch4
Select
F5-05
Channel 5
output selec-
tion
Effective when a DO-08 Dig-
ital Output Board is used.
Set the number of the multi-
function output to be output.
0 to 37 6 No A A A A A 39DH
6-164
DO Ch5
Select
F5-06
Channel 6
output selec-
tion
Effective when a DO-08 Dig-
ital Output Board is used.
Set the number of the multi-
function output to be output.
0 to 37 37 No A A A A A 39EH
6-164
DO Ch6
Select
F5-07
Channel 7
output selec-
tion
Effective when a DO-08 Dig-
ital Output Board is used.
Set the number of the multi-
function output to be output.
0 to 37 0F No A A A A A 39FH
6-165
DO Ch7
Select
F5-08
Channel 8
output selec-
tion
Effective when a DO-08 Dig-
ital Output Board is used.
Set the number of the multi-
function output to be output.
0 to 37 0F No A A A A A 3A0H
6-165
DO Ch8
Select
F5-09
DO-08 out-
put mode
selection
Effective when a DO-08 Dig-
ital Output Board is used.
Set the output mode.
0: 8-channel individual out-
puts
1: Binary code output
2: Output according to
F5-01 to F5-08 settings.
0 to 2 0 No A A A A A 3A1H
6-165
DO-08 Selec-
tion
TOE-S616-60.1.book 45 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals