246
Third Functions (Constants n080 to n119)
No. Register
No. for
Trans-
mission
Name Setting
Range
Setting Unit Factory
Setting
User
Setting
Ref.
Page
080 0150 Carrier Frequency Se-
lection
1 to 4, 7 to
9
1 4 (Note 4) 151
081 0151 Momentary Power Loss
Ridethrough Method
0 to 2 1 0 144
082 0152 Automatic Retry At-
tempts
0 to 10
times
1 0 148
083 0153 Jump Frequency 1 0.00 to
400.0 Hz
0.01 Hz (less
than 100 Hz)/
0.1 Hz (100 Hz
or more)
0.00 Hz 148
084 0154 Jump Frequency 2 0.00 to
400.0 Hz
0.01 Hz (less
than 100 Hz)/
0.1 Hz (100 Hz
or more)
0.00 Hz 148
085 0155 Jump Frequency 3 0.00 to
400.0 Hz
0.01 Hz (less
than 100 Hz)/
0.1 Hz (100 Hz
or more)
0.00 Hz 148
086 0156 Jump Frequency Range 0.00 to
25.50 Hz
0.01 Hz 0.00 Hz 148
089 0159 DC Injection Braking
Current
0% to
100%
1% 50% 150
090 015A DC Injection Braking
Time at Stop
0.0% to
25.5%
0.1s 0.5s
(Note 2)
156
091 015B DC Injection Braking
Time at Startup
0.0% to
25.5%
0.1s 0.0s 150
092 015C Stall Prevention During
Deceleration
0.1 1 0 170
093 015D Stall Prevention Level
During Acceleration
30% to
200%
1% 170% 167
094 015E Stall Prevention while
Running
30% to
200%
1% 160% 168
095 015F Frequency Detection
Level (Multi-function
Contact Output)
0.00 to
400.0 Hz
0.01 Hz (less
than 100 Hz)/
0.1 Hz (100 Hz
or more)
0.00 Hz 147
096 0160 Overtorque Detection
Function Selection 1
0 to 4 1 0 146
097 0161 Overtorque Detection
Function Selection 2
0.1 1 0 147
098 0162 Overtorque Detection
Level
30% to
200%
1% 160% 147
099 0163 Overtorque Detection
Time
0.1 to
10.0 s
0.1 s 0.1 s 147
100 0164 Hold Output Frequency
Saving Selection
0.1 1 0 161
103 0167 Torque Compensation
Gain
0.0 to 2.5 0.1 1.0 131

Table of Contents