EasyManua.ls Logo

YASKAWA Varispeed V7 - Page 87

YASKAWA Varispeed V7
256 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
86
* Terminal MA can be used only from DeviceNet communications. There is
no corresponding external output terminal.
Byte 1,
bit 7
Te r min al
P2
Indicates the output status of Inverter
multi-function output terminal P2.
0: Terminal P2 OFF
1: Terminal P2 ON
Bytes
2 and 3
Speed Ac-
tual
Indicates the Inverter’s speed.
The units depend on the setting in Invert-
er constant n035. The units are not af-
fected by the speed scale (SS) setting.
Bytes
4 and 5
Register
Number
Indicates the MEMOBUS register num-
ber in the executed process. These
bytes will contain the MEMOBUS error
code if a read or write error occurred.
Bytes
6 and 7
Register
Data
Indicates the read data when executing
a MEMOBUS READ command.
Data Name Contents

Table of Contents