5-67
IM 710105-17E
Commands
5
:ANALysis:PANalyze<x>:SWLoss:MEASure
:<Parameter>:COUNt?
Function Queries the continuous statistical processing
count of a power supply analysis parameter.
Syntax
:ANALysis:PANalyze<x>:SWLoss:MEASure:
P:COUNt?
<x> = 1 or 2
<Parameter> = {P|PABS|PN|PP|WH|WHABs|
WHN|WHP|Z}
Example
:ANALYSIS:PANALYZE1:SWLOSS:MEASURE:P:
COUNT?
-> :ANALYSIS:PANALYZE1:SWLOSS:MEASURE
:P:COUNT 100
:ANALysis:PANalyze<x>:SWLoss:MEASure
:<Parameter>:{MAXimum|MEAN|MINimum|S
DEViation}?
Function Queries a statistical value of a power supply
analysis parameter.
Syntax
:ANALysis:PANalyze<x>:SWLoss:MEASure:
<Parameter>:{MAXimum|MEAN|MINimum|
SDEViation}?
<x> = 1 or 2
<Parameter> = {P|PABS|PN|PP|WH|WHABs|
WHN|WHP|Z}
Example
:ANALYSIS:PANALYZE1:SWLOSS:MEASURE:P:
MAXIMUM?
-> :ANALYSIS:PANALYZE1:SWLOSS:MEASURE
:P:MAXIMUM 1.000E+00
Description If the statistical value is immeasurable, the
DLM2000 returns “NAN” (not a number).
:ANALysis:PANalyze<x>:SWLoss:MEASure
:<Parameter>:STATe
Function Sets or queries the on/off status of a power supply
analysis parameter.
Syntax
:ANALysis:PANalyze<x>:SWLoss:MEASure:
<Parameter>:STATe {<Boolean>}
:ANALysis:PANalyze<x>:SWLoss:MEASure:
<Parameter>:STATe?
<x> = 1 or 2
<Parameter> = {P|PABS|PN|PP|WH|WHABs|
WHN|WHP|Z}
Example
:ANALYSIS:PANALYZE1:SWLOSS:MEASURE:P:
STATE ON
:ANALYSIS:PANALYZE1:SWLOSS:MEASURE:P:
STATE?
-> :ANALYSIS:PANALYZE1:SWLOSS:MEASURE
:P:STATE 1
:ANALysis:PANalyze<x>:SWLoss:MEASure
:<Parameter>:VALue?
Function Queries an automatically measured value of a
power supply analysis parameter.
Syntax
:ANALysis:PANalyze<x>:SWLoss:MEASure:
<Parameter>:VALue? [{<NRf>}]
<x> = 1 or 2
<NRf> = See the DLM2000 Features Guide for
this information.
<Parameter> = {P|PABS|PN|PP|WH|WHABs|
WHN|WHP|Z}
Example
:ANALYSIS:PANALYZE1:SWLOSS:MEASURE:P:
VALUE?
-> :ANALYSIS:PANALYZE1:SWLOSS:MEASURE
:P:VALUE 10.0000E+03
Description • If the value is immeasurable, the DLM2000
returns “NAN” (not a number).
• The <NRf> is used to specify which iteration of
automated measurement to query the measured
value from.
• If <NRf> is set to 1, the oldest measured value
in the automated measurement memory is
queried.
• If a measured value does not exist at the
specified iteration, the DLM2000 returns “NAN”
(not a number).
• If <NRf> is omitted, the most recent measured
value is queried.
• If cyclic statistical processing for automated
measurement is being executed and <NRf> is
specified, the measured values over a cycle in
iteration <NRf> from the left of the display on
the displayed waveform is queried. If <NRf>
is omitted, the measured values over the last
cycle on the displayed waveform is queried.
:ANALysis:PANalyze<x>:SWLoss:METhod
Function Sets or queries the calculation method for high
and low points.
Syntax
:ANALysis:PANalyze<x>:SWLoss:METh
od {AUTO|MAXimum|HISTogram}
:ANALysis:PANalyze<x>:SWLoss:METhod?
<x> = 1 or 2
Example
:ANALYSIS:PANALYZE1:SWLOSS:METHOD
AUTO
:ANALYSIS:PANALYZE1:SWLOSS:METHOD?
-> :ANALYSIS:PANALYZE1:SWLOSS:METHOD
AUTO
5.3 ANALysis Group