EasyManua.ls Logo

YOKOGAWA DLM2000 Series - Page 99

YOKOGAWA DLM2000 Series
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-66
IM 710105-17E
:ANALysis:PANalyze<x>:SWLoss:ILEVel
Function Sets or queries the current level used to determine
the zero loss period for total loss computation.
Syntax
:ANALysis:PANalyze<x>:SWLoss:ILEV
el {<NRf>|<Current>}
:ANALysis:PANalyze<x>:SWLoss:ILEVel?
<x> = 1 or 2
<NRf>, <Current> = See the DLM2000 Features
Guide for this information.
Example
:ANALYSIS:PANALYZE1:SWLOSS:ILEVEL 1
:ANALYSIS:PANALYZE1:SWLOSS:ILEVEL?
-> :ANALYSIS:PANALYZE1:SWLOSS:
ILEVEL 1.0000000E+00
:ANALysis:PANalyze<x>:SWLoss:MATH
Function Sets or queries the on/off status of the power
waveform display.
Syntax
:ANALysis:PANalyze<x>:SWLoss:MATH {OF
F|POWer}
:ANALysis:PANalyze<x>:SWLoss:MATH?
<x> = 1 or 2
Example
:ANALYSIS:PANALYZE1:SWLOSS:MATH OFF
:ANALYSIS:PANALYZE1:SWLOSS:MATH?
-> :ANALYSIS:PANALYZE1:SWLOSS:MATH OF
F
:ANALysis:PANalyze<x>:SWLoss:MEASu
re?
Function Queries all of the settings for the automated
measurement of power supply analysis
parameters.
Syntax
:ANALysis:PANalyze<x>:SWLoss:MEASure?
<x> = 1 or 2
:ANALysis:PANalyze<x>:SWLoss:MEASure
:<Parameter>?
Function Queries the setting of a power supply analysis
parameter.
Syntax
:ANALysis:PANalyze<x>:SWLoss:MEASure:
<Parameter>?
<x> = 1 or 2
<Parameter> = {P|PABS|PN|PP|WH|WHABs|
WHN|WHP|Z}
:ANALysis:PANalyze<x>:SWLoss:DPROxim
al:PERCent
Function Sets or queries the distal, mesial, and proximal
points as percentages.
Syntax
:ANALysis:PANalyze<x>:SWLoss:DPROxima
l:PERCent {<NRf>,<NRf>,<NRf>}
:ANALysis:PANalyze<x>:SWLoss:DPROxima
l:PERCent?
<NRf>, <NRf>, <NRf> = 0 to 100 (%, in steps of 1)
<x> = 1 or 2
Example
:ANALYSIS:PANALYZE1:SWLOSS:DPROXIMAL:
PERCENT 10,50,90
:ANALYSIS:PANALYZE1:SWLOSS:DPROXIMAL:
PERCENT?
-> :ANALYSIS:PANALYZE1:SWLOSS:DPROXIM
AL:PERCENT 10,50,90
:ANALysis:PANalyze<x>:SWLoss:DPROxim
al:UNIT
Function Sets or queries the distal, mesial, and proximal
points as voltages.
Syntax
:ANALysis:PANalyze<x>:SWLoss:DPROxima
l:UNIT {<NRf>,<NRf>,<NRf>}
:ANALysis:PANalyze<x>:SWLoss:DPROxima
l:UNIT?
<NRf>, <NRf>, <NRf> = See the DLM2000
Features Guide for this information.
<x> = 1 or 2
Example
:ANALYSIS:PANALYZE1:SWLOSS:DPROXIMAL:
UNIT−1,0,1
:ANALYSIS:PANALYZE1:SWLOSS:DPROXIMAL:
UNIT?
-> :ANALYSIS:PANALYZE1:SWLOSS:DPROXIM
AL:UNIT−1.0000000E+00,
0.0000000E+00,1.0000000E+00
:ANALysis:PANalyze<x>:SWLoss:DTYPe
Function Sets or queries the device type for total loss
computation.
Syntax
:ANALysis:PANalyze<x>:SWLoss:DTY
Pe {IGBT|MOSFET|OFF}
:ANALysis:PANalyze<x>:SWLoss:DTYPe?
<x> = 1 or 2
Example
:ANALYSIS:PANALYZE1:SWLOSS:DTYPE IGBT
:ANALYSIS:PANALYZE1:SWLOSS:DTYPE?
-> :ANALYSIS:PANALYZE1:SWLOSS:DTYPE
5.3 ANALysis Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Related product manuals