5-164
IM 710105-17E
:SERialbus<x>:CANFD:SEARch:SETup[:ID
Data]:DATA:BCOunt
Function Sets or queries the pattern comparison position,
which is one of the ID and data conditions, for
CAN FD bus signal searching.
Syntax
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:BCOunt {<NRf>}
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:BCOunt?
<x> = 1 to 4
<NRf> = 0 to 63
Example
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:BCOUNT 4
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:BCOUNT?
-> :SERIALBUS1:CANFD:SEARCH:SETUP:IDD
ATA:DATA:BCOUNT 4
:SERialbus<x>:CANFD:SEARch:SETup[:ID
Data]:DATA:CONDition
Function Sets or queries the comparison condition, which is
one of the ID and data conditions, for CAN FD bus
signal searching.
Syntax
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:CONDition {BETWeen|EQUal|FA
LSe|GREater|LESS|NOTBetween|NOTEqul|T
RUE}
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:CONDition?
<x> = 1 to 4
Example
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:CONDITION BETWEEN
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:CONDITION?
-> :SERIALBUS1:CANFD:SEARCH:SETUP:IDD
ATA:DATA:CONDITION BETWEEN
:SERialbus<x>:CANFD:SEARch:SETup[:ID
Data]:DATA:DBYTe
Function Sets or queries the number of data types, which is
one of the ID and data conditions, for CAN FD bus
signal searching.
Syntax
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:DBYTe {<NRf>}
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:DBYTe?
<x> = 1 to 4
<NRf> = 0 to 8
Example
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:DBYTE 2
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:DBYTE?
-> :SERIALBUS1:CANFD:SEARCH:SETUP:IDD
ATA:DATA:DBYTE 2
:SERialbus<x>:CANFD:SEARch:SETup[:ID
Data]:DATA:DECimal<y>
Function Sets a reference value, which is one of the ID and
data conditions, for CAN FD bus signal searching
in decimal notation.
Syntax
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:DECimal<y> {<NRf>}
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:DECimal<y>?
<x> = 1 to 4
<y> = 1 or 2
<NRf> = –9E+18 to 9E+18
Example
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:DECIMAL1 1000
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:DECIMAL1?
-> :SERIALBUS1:CANFD:SEARCH:SETUP:IDD
ATA:DATA:DECIMAL1 1.0000000E+03
:SERialbus<x>:CANFD:SEARch:SETup[:ID
Data]:DATA:ENDian
Function Sets or queries the byte order of the reference
values, which is one of the ID and data conditions,
for CAN FD bus signal searching.
Syntax
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:ENDian {BIG|LITTle}
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:ENDian?
<x> = 1 to 4
Example
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:ENDIAN BIG
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:ENDIAN?
-> :SERIALBUS1:CANFD:SEARCH:SETUP:IDD
ATA:DATA:ENDIAN BIG
:SERialbus<x>:CANFD:SEARch:SETup[:ID
Data]:DATA:HEXa<y>
Function Sets a reference value, which is one of the ID and
data conditions, for CAN FD bus signal searching
in hexadecimal notation.
Syntax
:SERialbus<x>:CANFD:SEARch:SETup[:IDD
ata]:DATA:HEXa<y> {<String>}
<x> = 1 to 4
<y> = 1 to 8
Example
:SERIALBUS1:CANFD:SEARCH:SETUP:
IDDATA:DATA:HEXA1 "12"
5.24 SERialbus Group