EasyManua.ls Logo

YOKOGAWA DLM2000 Series - Page 203

YOKOGAWA DLM2000 Series
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-170
IM 710105-17E
:SERialbus<x>:FLEXray:SEARch:FJUMp:F
RAMeid
Function Jumps to the frame ID field in the FLEXRAY bus
signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:FR
AMeid
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:FRAM
EID
:SERialbus<x>:FLEXray:SEARch:FJUMp:H
CRC
Function Jumps to the Header CRC Field in the FLEXRAY
bus signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:HC
RC
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:HCRC
:SERialbus<x>:FLEXray:SEARch:FJUMp:P
LENgth
Function Jumps to the Payload Length Field in the
FLEXRAY bus signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:PL
ENgth
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:PLEN
GTH
:SERialbus<x>:FLEXray:SEARch:SELect
Function Sets the detected-waveform number of the
FLEXRAY bus signal search, or queries the zoom
location that corresponds to the number.
Syntax
:SERialbus<x>:FLEXray:SEARch:SELe
ct {<NRf>|MAXimum}
:SERialbus<x>:FLEXray:SEARch:SELect?
<x> = 1 to 4
<NRf> = 0 to 49999
Example
:SERIALBUS1:FLEXRAY:SEARCH:SELECT 0
:SERIALBUS1:FLEXRAY:SEARCH:SELECT?
-> :SERIALBUS1:FLEXRAY:SEARCH:SELECT
0
:SERialbus<x>:FLEXray:SEARch:SETup?
Function Queries all FLEXRAY bus signal search condition
settings.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup?
<x> = 1 to 4
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor?
Function Queries all FLEXRAY bus signal search error
settings.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror?
<x> = 1 to 4
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor:BSS
Function Sets or queries the FLEXRAY bus signal search
BSS error setting.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:BSS {<Boolean>}
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:BSS?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:BSS ON
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:BSS?
-> :SERIALBUS1:FLEXRAY:SEARCH:SETUP:E
RROR:BSS 1
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor:CRC
Function Sets or queries the FLEXRAY bus signal search
CRC error setting.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:CRC {<Boolean>}
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:CRC?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:CRC ON
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:CRC?
-> :SERIALBUS1:FLEXRAY:SEARCH:SETUP:E
RROR:CRC 1
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor:FES
Function Sets or queries the FLEXRAY bus signal search
FES error setting.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:FES {<Boolean>}
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:FES?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:FES ON
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:FES?
-> :SERIALBUS1:FLEXRAY:SEARCH:SETUP:E
RROR:FES 1
5.24 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series