5-170
IM 710105-17E
:SERialbus<x>:FLEXray:SEARch:FJUMp:F
RAMeid
Function Jumps to the frame ID field in the FLEXRAY bus
signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:FR
AMeid
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:FRAM
EID
:SERialbus<x>:FLEXray:SEARch:FJUMp:H
CRC
Function Jumps to the Header CRC Field in the FLEXRAY
bus signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:HC
RC
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:HCRC
:SERialbus<x>:FLEXray:SEARch:FJUMp:P
LENgth
Function Jumps to the Payload Length Field in the
FLEXRAY bus signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:PL
ENgth
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:PLEN
GTH
:SERialbus<x>:FLEXray:SEARch:SELect
Function Sets the detected-waveform number of the
FLEXRAY bus signal search, or queries the zoom
location that corresponds to the number.
Syntax
:SERialbus<x>:FLEXray:SEARch:SELe
ct {<NRf>|MAXimum}
:SERialbus<x>:FLEXray:SEARch:SELect?
<x> = 1 to 4
<NRf> = 0 to 49999
Example
:SERIALBUS1:FLEXRAY:SEARCH:SELECT 0
:SERIALBUS1:FLEXRAY:SEARCH:SELECT?
-> :SERIALBUS1:FLEXRAY:SEARCH:SELECT
0
:SERialbus<x>:FLEXray:SEARch:SETup?
Function Queries all FLEXRAY bus signal search condition
settings.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup?
<x> = 1 to 4
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor?
Function Queries all FLEXRAY bus signal search error
settings.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror?
<x> = 1 to 4
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor:BSS
Function Sets or queries the FLEXRAY bus signal search
BSS error setting.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:BSS {<Boolean>}
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:BSS?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:BSS ON
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:BSS?
-> :SERIALBUS1:FLEXRAY:SEARCH:SETUP:E
RROR:BSS 1
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor:CRC
Function Sets or queries the FLEXRAY bus signal search
CRC error setting.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:CRC {<Boolean>}
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:CRC?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:CRC ON
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:CRC?
-> :SERIALBUS1:FLEXRAY:SEARCH:SETUP:E
RROR:CRC 1
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor:FES
Function Sets or queries the FLEXRAY bus signal search
FES error setting.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:FES {<Boolean>}
:SERialbus<x>:FLEXray:SEARch:SETup:ER
Ror:FES?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:FES ON
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERRO
R:FES?
-> :SERIALBUS1:FLEXRAY:SEARCH:SETUP:E
RROR:FES 1
5.24 SERialbus Group