5-271
IM 710105-17E
Commands
5
:TRIGger[:ATRigger]:PSI5:DATA:HEXa
Function Sets the data for PSI5 signal triggering in
hexadecimal notation.
Syntax
:TRIGger[:ATRigger]:PSI5:DATA:HE
Xa {<String>}
Example
:TRIGGER:ATRIGGER:PSI5:DATA:HE
XA "3A0F"
Description This command is valid when
:TRIGger[:ATRig
ger]:PSI5:DATA:CONDition
is
TRUE
.
:TRIGger[:ATRigger]:PSI5:DATA:PATTe
rn
Function Sets or queries the data for PSI5 signal triggering
in binary notation.
Syntax
:TRIGger[:ATRigger]:PSI5:DATA:PATTe
rn {<String>}
:TRIGger[:ATRigger]:PSI5:DATA:PATTe
rn?
Example
:TRIGGER:ATRIGGER:PSI5:DATA:PATTE
RN "0011010100001111"
:TRIGGER:ATRIGGER:PSI5:DATA:PATTERN?
-> :TRIGGER:ATRIGGER:PSI5:DATA:PATTE
RN "0011010100001111"
Description This command is valid when
:TRIGger[:ATRig
ger]:PSI5:DATA:CONDition
is
TRUE
.
:TRIGger[:ATRigger]:PSI5:DATA:PFORm
at
Function Sets or queries the data input format for PSI5
signal triggering.
Syntax
:TRIGger[:ATRigger]:PSI5:DATA:PFORm
at {BINary|HEXa}
:TRIGger[:ATRigger]:PSI5:DATA:PFORm
at?
Example
:TRIGGER:ATRIGGER:PSI5:DATA:PFORM
AT BINARY
:TRIGGER:ATRIGGER:PSI5:DATA:PFORMAT?
-> :TRIGGER:ATRIGGER:PSI5:DATA:PFORM
AT BINARY
:TRIGger[:ATRigger]:PSI5:MODE
Function Sets or queries the PSI5 signal trigger mode.
Syntax
:TRIGger[:ATRigger]:PSI5:MODE {DATA|S
BIT|SYNC}
:TRIGger[:ATRigger]:PSI5:MODE?
Example
:TRIGGER:ATRIGGER:PSI5:MODE DATA
:TRIGGER:ATRIGGER:PSI5:MODE?
-> :TRIGGER:ATRIGGER:PSI5:MODE DATA
:TRIGger[:ATRigger]:PSI5:SETup?
Function Queries all bus setup settings for PSI5 signal
triggering.
Syntax
:TRIGger[:ATRigger]:PSI5:SETup?
:TRIGger[:ATRigger]:PSI5:SETup:DATA?
Function Queries all PSI5 signal trigger data signal settings.
Syntax
:TRIGger:ATRigger:PSI5:SETup:DATA?
:TRIGger[:ATRigger]:PSI5:SETup:DATA:
BRATe
Function Sets or queries the PSI5 signal trigger bit rate (data
transfer rate).
Syntax
:TRIGger[:ATRigger]:PSI5:SETup:DATA:B
RATe {<NRf>|USER,<NRf>}
:TRIGger[:ATRigger]:PSI5:SETup:DATA:B
RATe?
<NRf> = 125000, 189000
USER <NRf> = See the DLM2000 Features Guide
for this information.
Example
:TRIGGER:ATRIGGER:PSI5:SETUP:DATA:BRA
TE 125000
:TRIGGER:ATRIGGER:PSI5:SETUP:DATA:BRA
TE?
-> :TRIGGER:ATRIGGER:PSI5:SETUP:DATA:
BRATE 125000
5.33 TRIGger Group