5-69
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
:ANALysis:PANalyze<x>:SOA:CURSor:X<y
>:POSition
Function Sets or queries a horizontal cursor position in the
XY display (safe operating area).
Syntax
:ANALysis:PANalyze<x>:SOA:CURSor:X<y
>:POSition {<NRf>}
:ANALysis:PANalyze<x>:SOA:CURSor:X<y
>:POSition?
<x> = 1 to 2
<y> = 1 to 2
<NRf> = −4 to 4 (divisions)
Example
:ANALYSIS:PANALYZE1:SOA:CURSOR:X1:PO
SITION 1
:ANALYSIS:PANALYZE1:SOA:CURSOR:X1:PO
SITION?
-> :ANALYSIS:PANALYZE1:SOA:CURSOR:X1
:POSITION 1.000E+00
:ANALysis:PANalyze<x>:SOA:CURSor:X<y
>:VALue?
Function Sets or queries the voltage value of a horizontal
cursor in the XY display (safe operating area).
Syntax
:ANALysis:PANalyze<x>:SOA:CURSor:X<y
>:VALue?
<x> = 1 to 2
<y> = 1 to 2
Example
:ANALYSIS:PANALYZE1:SOA:CURSOR:X1:VA
LUE?
-> :ANALYSIS:PANALYZE1:SOA:CURSOR:X1
:VALUE 1.000E+00
:ANALysis:PANalyze<x>:SOA:CURSor:Y
<y>?
Function Queries all XY display (safe operating area)
vertical cursor settings.
Syntax
:ANALysis:PANalyze<x>:SOA:CURSor:Y
<y>?
<x> = 1 to 2
<y> = 1 to 2
:ANALysis:PANalyze<x>:SOA:CURSor:Y<y
>:POSition
Function Sets or queries a vertical cursor position in the
XY display (safe operating area).
Syntax
:ANALysis:PANalyze<x>:SOA:CURSor:Y<y
>:POSition {<NRf>}
:ANALysis:PANalyze<x>:SOA:CURSor:Y<y
>:POSition?
<x> = 1 to 2
<y> = 1 to 2
<NRf> = −4 to 4 (divisions)
Example
:ANALYSIS:PANALYZE1:SOA:CURSOR:Y1:PO
SITION 1
:ANALYSIS:PANALYZE1:SOA:CURSOR:Y1:PO
SITION?
-> :ANALYSIS:PANALYZE1:SOA:CURSOR:Y1
:POSITION 1.000E+00
:ANALysis:PANalyze<x>:SETup:U:PROBe
Function Sets or queries the probe attenuation setting
of the voltage input channel for power supply
analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:U:PRO
Be {<NRf>}
:ANALysis:PANalyze<x>:SETup:U:PROBe?
<x> = 1 to 2
<NRf> = See the DLM4000 Features Guide for
this information.
Example
:ANALYSIS:PANALYZE1:SETUP:U:PROBE 1
:ANALYSIS:PANALYZE1:SETUP:U:PROBE?
-> :ANALYSIS:PANALYZE1:SETUP:U:PROB
E 1.000
:ANALysis:PANalyze<x>:SETup:RTRace
Function Sets or queries the reference trace for power
supply analysis deskewing.
Syntax
:ANALysis:PANalyze<x>:SETup:RTRa
ce {I|U}
:ANALysis:PANalyze<x>:SETup:RTRace?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:SETUP:RTRACE I
:ANALYSIS:PANALYZE1:SETUP:RTRACE?
-> :ANALYSIS:PANALYZE1:SETUP:RTRA
CE I
:ANALysis:PANalyze<x>:SOA?
Function Queries all XY display (safe operating area)
settings.
Syntax
:ANALysis:PANalyze<x>:SOA?
<x> = 1 to 2
:ANALysis:PANalyze<x>:SOA:CURSor?
Function Queries all XY display (safe operating area)
cursor measurement settings.
Syntax
:ANALysis:PANalyze<x>:SOA:CURSor?
<x> = 1 to 2
:ANALysis:PANalyze<x>:SOA:CURSor:X
<y>?
Function Queries all XY display (safe operating area)
horizontal cursor settings.
Syntax
:ANALysis:PANalyze<x>:SOA:CURSor:X
<y>?
<x> = 1 to 2
<y> = 1 to 2
5.3 ANALysis Group