Page #125 background imageLoading...
Page #125 background image
5-92
IM DLM4038-17EN
:CURSor[:TY]:MARKer:M<x>:TRACe
Function Sets or queries the source waveform that you
want to measure using the marker cursors.
Syntax
:CURSor[:TY]:MARKer:M<x>:TRACe {<NRf
>|MATH<y>|OFF}
:CURSor[:TY]:MARKer:M<x>:TRACe?
<x> = 1 to 4
<NRf> = 1 to 8
<y> = 1 to 4
Example
:CURSOR:TY:MARKER:M1:TRACE 1
:CURSOR:TY:MARKER:M1:TRACE?
-> :CURSOR:TY:MARKER:M1:TRACE 1
:CURSor[:TY]:MARKer:M<x>:V?
Function Queries all vertical axis settings for a marker
cursor.
Syntax
:CURSor[:TY]:MARKer:M<x>:V?
<x> = 1 to 4
:CURSor[:TY]:MARKer:M<x>:V:STATe
Function Sets or queries the on/off status of the vertical
value of a marker cursor.
Syntax
:CURSor[:TY]:MARKer:M<x>:V:STA
Te {<Boolean>}
:CURSor[:TY]:MARKer:M<x>:V:STATe?
<x> = 1 to 4
Example
:CURSOR:TY:MARKER:M1:V:STATE ON
:CURSOR:TY:MARKER:M1:V:STATE?
-> :CURSOR:TY:MARKER:M1:V:STATE 1
:CURSor[:TY]:MARKer:M<x>:V:VALue?
Function Queries the vertical value of a marker cursor.
Syntax
:CURSor[:TY]:MARKer:M<x>:V:VALue?
<x> = 1 to 4
Example
:CURSOR:TY:MARKER:M<x>:V:VALUE?
-> :CURSOR:TY:MARKER:M1:V:VALUE 1.50
00E−03
Description If
:CHANnel<x>:LSCale:MODE
is set to ON,
the scaled value will be queried.
:CURSor[:TY]:TYPE
Function Sets or queries the cursor type.
Syntax
:CURSor[:TY]:TYPE {DEGRee|HAVertical
|HORizontal|MARKer|OFF|VERTical}
:CURSor[:TY]:TYPE?
Example
:CURSOR:TY:TYPE HORizontal
:CURSOR:TY:TYPE?
-> :CURSOR[:TY]:TYPE HORizontal
:CURSor[:TY]:VERTical?
Function Queries all ΔT cursor settings.
Syntax
:CURSor[:TY]:VERTical?
:CURSor[:TY]:VERTical:ALL
Function Collectively turns on or off the measured values
of the ΔT cursor on the T-Y display.
Syntax
:CURSor:TY:VERTical:ALL {<Boolean>}
Example
:CURSOR:TY:VERTICAL:ALL ON
:CURSor[:TY]:VERTical:DT?
Function Queries all time axis settings for the ΔT cursors.
Syntax
:CURSor[:TY]:VERTical:DT?
:CURSor[:TY]:VERTical:DT:STATe
Function Sets or queries the on/off status of the time value
measured between the ΔT cursors.
Syntax
:CURSor[:TY]:VERTical:DT:STATe {<Boo
lean>}
:CURSor[:TY]:VERTical:DT:STATe?
Example
:CURSOR[:TY]:VERTICAL:DT:STATE ON
:CURSOR:TY:VERTICAL:DT:STATE?
-> :CURSOR:TY:VERTICAL:DT:STATE 1
:CURSor[:TY]:VERTical:DT:VALue?
Function Queries the time value between the ΔT cursors.
Syntax
:CURSor[:TY]:VERTical:DT:VALue?
Example
:CURSOR:TY:VERTICAL:DT:VALUE?
-> :CURSOR:TY:VERTICAL:DT:VALU
E2.50E−06
:CURSor[:TY]:VERTical:DV?
Function Queries all vertical axis settings for the ΔT
cursors.
Syntax
:CURSor[:TY]:VERTical:DV?
:CURSor[:TY]:VERTical:DV:STATe
Function Sets or queries the on/off status of the vertical
value measured between the T cursors.
Syntax
:CURSor[:TY]:VERTical:DV:STATe {<Boo
lean>}
:CURSor[:TY]:VERTical:DV:STATe?
Example
:CURSOR:TY:VERTICAL:DV:STATE ON
:CURSOR:TY:VERTICAL:DV:STATE?
-> :CURSOR:TY:VERTICAL:DV:STATE 1
:CURSor[:TY]:VERTical:DV:VALue?
Function Queries the vertical value between the ΔT
cursors.
Syntax
:CURSor[:TY]:VERTical:DV:VALue?
Example
:CURSOR:TY:VERTICAL:DV:VALUE?
-> :CURSOR:TY:VERTICAL:DV:VALUE 1.50
E+03
Description If
:CHANnel<x>:LSCale:MODE
is set to ON,
the scaled value will be queried.
5.10 CURSor Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals