EasyManuals Logo

YOKOGAWA DLM4038 User Manual

YOKOGAWA DLM4038
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #176 background imageLoading...
Page #176 background image
5-143
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
:MEASure:CYCLe:TRACe
Function Sets or queries the source waveform used in
the cyclic statistical processing for automated
measurement.
Syntax
:MEASure:CYCLe:TRACe {OWN|<NRf>|
MATH<x>|PODA<x>|PODB<x>|PODL<x>}
:MEASure:CYCLe:TRACe?
<NRf> = 1 to 8
<x> of MATH<x> = 1 to 4
<x> of PODA<x>, PODB<x>, PODL<x> = 0 to 7
Example
:MEASURE:CYCLE:TRACE 1
:MEASURE:CYCLE:TRACE?
-> :MEASURE:CYCLE:TRACE 1
:MEASure:HISTory:ABORt
Function Aborts statistical processing of automatically
measured history waveforms.
Syntax
:MEASure:HISTory:ABORt
Example
:MEASURE:HISTORY:ABORT
:MEASure:HISTory:EXECute
Function Executes statistical processing of automatically
measured history waveforms.
Example
:MEASURE:HISTORY:EXECUTE
:MEASure:INDicator
Function Sets or queries the measurement location
indicator.
Syntax
:MEASure:INDicator {<NRf>|MATH<x>|
PODA<x>|PODB<x>|PODL<x>|
OFF{,<Parameter>[,2]}}
:MEASure:INDicator?
<NRf> = 1 to 8
<x> of MATH<x> = 1 to 4
<x> of PODA<x>, PODB<x>, PODL<x> = 0 to 7
<Parameter> =
{AMPLitude|AVERage|
AVGFreq|AVGPeriod|BWIDth|DELay|
DUTYcycle|FALL|FREQuency|HIGH|LOW|
MAXimum|MINimum|NOVershoot|NWIDth|
P|PABS|PERiod|PN|POVershoot|PP|
PTOPeak|PWIDth|RISE|RMS|V1|V2|WH|
WHABs|WHN|WHP|Z}
Example
:MEASURE:INDICATOR 1,AVERAGE
:MEASURE:INDICATOR?
-> :MEASURE:INDICATOR 1,AVERAGE
:MEASure:MODE
Function Sets or queries the on/off/statistical processing
status of automated measurement.
Syntax
:MEASure:MODE {OFF|ON|CONTinuous|
CYCLe|HISTory}
:MEASure:MODE?
Example
:MEASURE:MODE OFF
:MEASURE:MODE?
-> :MEASURE:MODE OFF
:MEASure:{PODA<x>|PODB<x>|PODL<x>}?
Function Queries all the parameter on/off status of the
logic waveform.
Syntax
:MEASure:{PODA<x>|PODB<x>|PODL<x>}?
<x> = 0 to 7
:MEASure:{PODA<x>|PODB<x>|PODL<x>}
{[:AREA1]|:AREA2}?
Function Queries all the parameter on/off status of the
logic waveform in the specified area.
Syntax
:MEASure:{PODA<x>|PODB<x>|PODL<x>}
{[:AREA1]|:AREA2}?
<x> = 0 to 7
:MEASure:{PODA<x>|PODB<x>|PODL<x>}
{[:AREA1]|:AREA2}:ALL
Function Collectively turns on or off all measurement items
of a logic waveform in the specified area.
Syntax
:MEASure:{PODA<x>|PODB<x>|PODL<x>}
{[:AREA1]|:AREA2}ALL {<Boolean>}
<x> = 0 to 7
Example
:MEASURE:PODL1:AREA1:ALL ON
:MEASure:{PODA<x>|PODB<x>|PODL<x>}
{[:AREA1]|:AREA2}:<Parameter>?
Function Queries the setting of a logic waveform parameter
in the specified area.
Syntax
:MEASure:{PODA<x>|PODB<x>|PODL<x>}
{[:AREA1]|:AREA2}:<Parameter>?
<x> = 0 to 7
<Parameter> =
{AVGFreq|DELay|DUTYcycle
|FREQuency|PERiod|PNUMber}
:MEASure:{PODA<x>|PODB<x>|PODL<x>}{[
:AREA1]|:AREA2}:<Parameter>:COUNt?
Function Queries the statistical processing count of a logic
waveform parameter in the specified area.
Syntax
:MEASure:{PODA<x>|PODB<x>|PODL<x>}{[
:AREA1]|:AREA2}:<Parameter>:COUNt?
<x> = 0 to 7
<Parameter> =
{AVGFreq|DELay|DUTYcycle
|FREQuency|PERiod|PNUMber}
Example
:MEASURE:PODL:AREA1:AVGFREQ:COUNT?
-> :MEASURE:PODL:AREA1:AVGFREQ:COUN
T 100
5.21 MEASure Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals