EasyManuals Logo

YOKOGAWA DLM4038 User Manual

YOKOGAWA DLM4038
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #233 background imageLoading...
Page #233 background image
5-200
IM DLM4038-17EN
:SERialbus<x>:LIN:SEARch:SETup:MODE
Function Sets or queries the LIN bus signal search mode
setting.
Syntax
:SERialbus<x>:LIN:SEARch:SETup:MO
DE {BSYNch|ERRor|IDData}
:SERialbus<x>:LIN:SEARch:SETup:MODE?
<x> = 1 to 4
Example
:SERIALBUS1:LIN:SEARCH:SETUP:MODE BS
YNCH
:SERIALBUS1:LIN:SEARCH:SETUP:MODE?
-> :SERIALBUS1:LIN:SEARCH:SETUP:MOD
E BSYNCH
:SERialbus<x>:PSI5?
Function Queries all PSI5 signal analysis and search
settings.
Syntax
:SERialbus<x>:PSI5?
<x> = 1 to 4
:SERialbus<x>:PSI5:ANALyze?
Function Queries all PSI5 signal analysis settings.
Syntax
:SERialbus<x>:PSI5:ANALyze?
<x> = 1 to 4
:SERialbus<x>:PSI5[:ANALyze]:SETup?
Function Queries all bus setup settings for PSI5 signal
analysis.
Syntax
:SERialbus<x>:PSI5[:ANALyze]:SETup?
<x> = 1 to 4
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA?
Function Queries all PSI5 signal analysis data signal
settings.
Syntax
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA?
<x> = 1 to 4
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:BRATe
Function Sets or queries the PSI5 signal analysis bit rate
(data transfer rate).
Syntax
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:BRATe {<NRf>|USER,<NRf>}
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:BRATe?
<x> = 1 to 4
<NRf> = 125000, 189000
USER <NRf> = See the DLM4000 Features
Guide for this information.
Example
:SERIALBUS1:PSI5:ANALYZE:SETUP:DATA:
BRATE 125000
:SERIALBUS1:PSI5:ANALYZE:SETUP:DATA:
BRATE?
-> :SERIALBUS1:PSI5:ANALYZE:SETUP:DA
TA:BRATE 125000
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:CTOLerance
Function Sets or queries the PSI5 signal analysis clock
tolerance.
Syntax
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:CTOLerance {<NRf>}
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:CTOLerance?
<NRf> = ±0.5% to ±33.3% (resolution:0.1%)
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:ANALYZE:SETUP:DATA:
CTOLERANCE 5
:SERIALBUS1:PSI5:ANALYZE:SETUP:DATA:
CTOLERANCE?
-> :SERIALBUS1:PSI5:ANALYZE:SETUP:DA
TA:CTOLERANCE 5.00E+00
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:DBITs
Function Sets or queries the data length for PSI5 signal
analysis.
Syntax
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:DBITs {<NRf>}
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:DBITs?
<x> = 1 to 4
<NRf> = 10, 16
Example
:SERIALBUS1:PSI5:ANALYZE:SETUP:DATA:
DBITS 10
:SERIALBUS1:PSI5:ANALYZE:SETUP:DATA:
DBITS?
-> :SERIALBUS1:PSI5:ANALYZE:SETUP:DA
TA:DBITS 10
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:EDETection
Function Sets or queries the error detection method for
PSI5 signal analysis.
Syntax
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:EDETection {CRC|PARity}
:SERialbus<x>:PSI5[:ANALyze]:SETup:D
ATA:EDETection?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:ANALYZE:SETUP:DATA:
EDETECTION CRC
:SERIALBUS1:PSI5:ANALYZE:SETUP:DATA:
EDETECTION?
-> :SERIALBUS1:PSI5:ANALYZE:SETUP:DA
TA:EDETECTION CRC
5.25 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals