5-205
IM DLM4038-17EN
Commands
5
:SERialbus<x>:PSI5:SEARch[:SETup]:ER
Ror:SBOundary
Function Sets or queries the PSI5 signal slot boundary
error search.
Syntax
:SERialbus<x>:PSI5:SEARch[:SETup]:ER
Ror:SBOundary {<Boolean>}
:SERialbus<x>:PSI5:SEARch[:SETup]:ER
Ror:SBOundary?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:SEARCH:SETUP:ERROR:
SBOUNDARY ON
:SERIALBUS1:PSI5:SEARCH:SETUP:ERROR:
SBOUNDARY?
-> :SERIALBUS1:PSI5:SEARCH:SETUP:ERR
OR:SBOUNDARY 1
:SERialbus<x>:PSI5:SEARch[:SETup]:FR
AMeinslot?
Function Queries all PSI5 signal slot specification search
settings.
Syntax
:SERialbus<x>:PSI5:SEARch[:SETup]:FR
AMeinslot?
<x> = 1 to 4
:SERialbus<x>:PSI5:SEARch[:SETup]:FR
AMeinslot:SNUMber
Function Sets or queries the slot number of the PSI5 signal
slot specification search.
Syntax
:SERialbus<x>:PSI5:SEARch[:SETup]:FR
AMeinslot:SNUMber {<NRf>}
:SERialbus<x>:PSI5:SEARch[:SETup]:FR
AMeinslot:SNUMber?
<x> = 1 to 4
<NRf> = 1 to 6
Example
:SERIALBUS1:PSI5:SEARCH:SETUP:FRAMEI
NSLOT:SNUMBER 1
:SERIALBUS1:PSI5:SEARCH:SETUP:FRAMEI
NSLOT:SNUMBER?
-> :SERIALBUS1:PSI5:SEARCH:SETUP:FRA
MEINSLOT:SNUMBER 1
:SERialbus<x>:PSI5:SEARch[:SETup]:MO
DE
Function Sets or queries the PSI5 signal search mode
setting.
Syntax
:SERialbus<x>:PSI5:SEARch[:SETup]:
MODE {DATA|ERRor|FRAMeinslot|SBIT|SY
NC}
:SERialbus<x>:PSI5:SEARch[:SETup]:MO
DE?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:SEARCH:SETUP:MO
DE DATA
:SERIALBUS1:PSI5:SEARCH:SETUP:MODE?
-> :SERIALBUS1:PSI5:SEARCH:SETUP:MO
DE DATA
:SERialbus<x>:PSI5:TRENd<y>?
Function Queries all PSI5 signal analysis trend display
settings.
Syntax
:SERialbus<x>:PSI5:TRENd<y>?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:PSI5:TRENd<y>:ASCale
Function Executes auto scaling of the PSI5 signal analysis
trend display.
Syntax
:SERialbus<x>:PSI5:TRENd<y>:ASCale
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:PSI5:TREND1:ASCALE
:SERialbus<x>:PSI5:TRENd<y>:CURSor?
Function Queries all PSI5 signal analysis trend display
cursor measurement settings.
Syntax
:SERialbus<x>:PSI5:TRENd<y>:CURSor?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:PSI5:TRENd<y>:CURSor:D
T:VALue?
Function Queries the time value between cursors on the
PSI5 signal analysis trend display.
Syntax
:SERialbus<x>:PSI5:TRENd<y>:CURSor:D
T:VALue?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:PSI5:TRENd<y>:CURSor:D
V:VALue?
Function Queries the vertical value between cursors on the
PSI5 signal analysis trend display.
Syntax
:SERialbus<x>:PSI5:TRENd<y>:CURSor:D
V:VALue?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:PSI5:TRENd<y>:CURSor:M
ODE
Function Sets or queries the cursor mode on the PSI5
signal analysis trend display.
Syntax
:SERialbus<x>:PSI5:TRENd<y>:CURSor:M
ODE {<Boolean>}
:SERialbus<x>:PSI5:TRENd<y>:CURSor:M
ODE?
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:PSI5:TREND1:CURSOR:MO
DE ON
:SERIALBUS1:PSI5:TREND1:CURSOR:MODE?
-> :SERIALBUS1:PSI5:TREND1:CURSOR:MO
DE 1
5.25 SERialbus Group